2314 search results for apl

9950201-724IMPL

for listing on the APL, sample data collected from the vehicle detection system will be compared against, on the APL, sample data collected from the vehicle detection system will be compared against ground, requirements in this Section and as a precondition for listing on the APL, sample data collected from, backplates must fit all traffic signals listed on the APL. Mount the backplate securely, listed on the APL. Place a 2-inch border on the entire outer perimeter of the backplate panel

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/fy-2024-25/review/implemented/9950201-724impl.pdf?sfvrsn=a8a22562_1

9970000-724FHWA

APL equipment. Any electronics unit or software submitted for approval must be compatible, : All products shall be listed on the Department’s Approved Product List (APL). Manufacturers seeking evaluation of their product for inclusion on the APL shall submit an application in accordance, with all other TMS APL equipment. Any electronics unit or software submitted for approval must

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/fy-2024-25/review/fhwa/9970000-724fhwa.pdf?sfvrsn=29987614_1

4551508-724FHWA

structures, polymer slurry may be mixed in the casing portion, in accordance with the APL approved, by the APL Marsh Cone Method: FM 8-RP13B-2 Viscosity for miscellaneous structure foundations 50, by the APL Marsh Cone Method: FM 8-RP13B-2 pH Range published by the manufacturer for materials, structures, polymer slurry may be mixed in the casing portion, in accordance with the APL approved, Viscosity for bridges and main structure foundations 50 seconds to upper limit defined by the APL

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/fy-2024-25/review/fhwa/4551508-724fhwa.pdf?sfvrsn=749486ee_2

v1-section31-clean

Products List (APL) and are referenced in the Producer’s QC Plan. D) The warm mix technology being, Approved Product List (APL). F) A copy of the Bill of Lading representing the prime coat or tack coat, on the APL. I) Warm Mix Designs Transfer requests of a hot mix asphalt design to a warm mix

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/materials/administration/resources/library/publications/materialsmanual/documents/v1-section31-clean.pdf?sfvrsn=f53d16b8_15

9970000-724IMPL

 997 TRAFFIC MONITORING SITE MATERIALS. (REV 10-16-23) (FA 10-31-23) (FY 2024-25) SECTION 997 is deleted and the following substituted: 997-1 Description. This Section governs the requirements for all traffic monitoring site (TMS) material as shown in the Plans and Standard Plans. Provide products compatible with all other TMS APL equipment. Any electronics unit or software submitted, Approved Product List (APL). Manufacturers seeking evaluation of their product for inclusion on the APL

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/fy-2024-25/review/implemented/9970000-724impl.pdf?sfvrsn=fff0cf45_1

4551508-724CommResp

, and ITS structures, polymer slurry may be mixed in the casing portion, in accordance with the APL, to upper limit defined by the APL Marsh Cone Method: FM 8-RP13B-2 Viscosity for miscellaneous, water) Mud density balance: FM 8-RP13B-1 Viscosity 50 seconds to upper limit defined by the APL

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/fy-2024-25/review/comments-responses/4551508-724commresp.pdf?sfvrsn=fee74b29_2

7850000.impl

specifications, and are listed on the Department’s Approved Product List (APL). The lowering device must, on the Department’s APL. 785-3.2 Materials: 785-3.2.1 Cabinet Shell: Ensure the cabinet shell conforms to NEMA, wiring harnesses and connectors. Ensurethatthecabinetmanufacturer’sname and APL certification number

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2014/july-2014/review/implemented/7850000.impl.pdf?sfvrsn=12fdd200_0

SS7840000

Product List (APL). 784-1.2 M a t e r i a l s : 7 8 4 - 1 . 2 . 1 G e n e r a l : E n sure that the ITS, on the Department’s Approved Product List (APL). 784-2.2 M a t e r i a l s : 7 8 4 - 2 . 2 . 1 G e n e r a l : E n, specifications, and are listed on the Department’s Approved Product List (APL). 784-3.2 M a t e r

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2010/january-2010/workbook/ss7840000.pdf?sfvrsn=6a637b7d_0

SS7820000

on the Department’s Approved Product List (APL). For analog cameras, ensure that the camera produces, Control System listed on the APL. Ensure that the video display control system enables the operator, and displaying all video streams produced by encoders listed on the APL. Use a video display control

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2012/january-2012/workbook/ss7820000.pdf?sfvrsn=d4c13fa1_0

521-010

with a maximum spacing of 50'-0" and a minimum spacing of 2 1 3. TRANSVERSE JOINTS: Place the APL

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/design/standardplans/2025/idx/521-010.pdf?sfvrsn=18dafe2b_1

676-010

dimensions per the APL. 7. Locate generator connection panel at bottom of cabinet assembly. 6. Locate

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/design/standardplans/2025/idx/676-010.pdf?sfvrsn=14550915_1
20 of 2314 results