834 search results for fencing
550-012FHWAApprovedPkg
: REVISION LAST of STANDARD PLANS FY 2023-24 SHEET INDEX BRIDGE FENCING (ENCLOSED) 11/01/17 1 4, , tension bars and bands, pipe clamps, Payment will be made under Fencing, Type R. Payment includes posts, of fencing are from begin of approach slab at Begin Bridge to end of approach slab at End Bridge, unless otherwise LIMITS OF FENCING: railing as shown on Index 521-820. See Index 521-820 - Pedestrian/Bicycle Railing for Concrete Parapet details. Provide fencing in lieu of aluminum bullet CONCRETE
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/design/standardplans/irr/2025/550-012fhwaapprovedpkg.pdf?sfvrsn=ed58486e_1SPM5500100 InternalCommentResponse
Date: 12-27-2024 COMMENT: Concerning fencing, could we address vegetation removal as well
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/fy-2025-26/maintenance/comments-responses/spm5500100-internalcommentresponse.pdf?sfvrsn=96ca4967_15500407.comm
5500407 FENCING COMMENTS FROM INTERNAL/INDUSTRY REVIEW David Sadler 414-5203 david.sadler@dot.state.fl.us Comments: (10-24-17, Internal) As written spec addresses 550-4.7.1 grounding for overhead lines and 550-4.7.2 fences with non- metal posts. Is the second subarticle intended to be in a condition where there is an overhead powerline or in the vicinity of one or is it for any fence regardless of its proximity to an overhead powerline? Response: This would be regardless
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2018/july-2018/review/comments-responses/5500407.comm.pdf?sfvrsn=f8cfdf4c_05500407.resp
5500407 FENCING COMMENTS FROM INTERNAL/INDUSTRY REVIEW David Sadler 414-5203 david.sadler@dot.state.fl.us Comments: (10-24-17, Internal) As written spec addresses 550-4.7.1 grounding for overhead lines and 550-4.7.2 fences with non- metal posts. Is the second subarticle intended to be in a condition where there is an overhead powerline or in the vicinity of one or is it for any fence regardless of its proximity to an overhead powerline? Response: This would be regardless
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2018/july-2018/review/comments-responses/5500407.resp.pdf?sfvrsn=8c26a6fe_05500021SP
FENCING. (REV 1-6-98) (7-00) ARTICLE 550-2 (of the Supplemental Specifications) is deleted and the following substituted: 550-2 Types of Fence. Thetypeoffencetobeconstructedisdesignatedasfollows: TypeA(Farm Fence). Fabric:Galvanizedsteelwovenwirefarm fence. Line P o s t s : R e c y c l e d P l a s t i c . Corner,PullandEndPostAssemblies: Galvanized steel, timber, recycled plastic or concrete as specified in the Design Standards. TypeB(Chain-LinkFence). Metalposts
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2005/january-2005/workbook/5500021sp.pdf?sfvrsn=bf265bc9_05500021SP
FENCING. (REV 1-6-98) (7-00) ARTICLE 550-2 (of the Supplemental Specifications) is deleted and the following substituted: 550-2 Types of Fence. Thetypeoffencetobeconstructedisdesignatedasfollows: TypeA(Farm Fence). Fabric:Galvanizedsteelwovenwirefarm fence. Line P o s t s : R e c y c l e d P l a s t i c . Corner,PullandEndPostAssemblies: Galvanized steel, timber, recycled plastic or concrete as specified in the Design Standards. TypeB(Chain-LinkFence). Metalposts
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2006/january-2006/workbook/5500021sp.pdf?sfvrsn=306a0e68_0SP5500200
FENCING. (REV 1-6-98) (7-00) ARTICLE 550-2 (Page 623) is deleted and the following substituted: 550-2 Types of Fence. Thetypeoffencetobeconstructedisdesignatedasfollows: TypeA(Farm Fence). Fabric:Galvanizedsteelwovenwirefarm fence. Line P o s t s : R e c y c l e d P l a s t i c . Corner,PullandEndPostAssemblies: Galvanized steel, timber, recycled plastic or concrete as specified in the Design Standards. TypeB(Chain-LinkFence). Metalposts
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2007/january-2007/workbook/sp5500200.pdf?sfvrsn=a6856a98_0SP5500200
FENCING. (REV 1-6-98) (7-00) ARTICLE 550-2 (Page 623) is deleted and the following substituted: 550-2 Types of Fence. Thetypeoffencetobeconstructedisdesignatedasfollows: TypeA(Farm Fence). Fabric:Galvanizedsteelwovenwirefarm fence. Line P o s t s : R e c y c l e d P l a s t i c . Corner,PullandEndPostAssemblies: Galvanized steel, timber, recycled plastic or concrete as specified in the Design Standards. TypeB(Chain-LinkFence). Metalposts
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2008/january-2008/workbook/sp5500200.pdf?sfvrsn=1dc79f6b_0SP5500200
FENCING. (REV 1-6-98) (7-00) ARTICLE 550-2 (Page 623) is deleted and the following substituted: 550-2 Types of Fence. Thetypeoffencetobeconstructedisdesignatedasfollows: TypeA(Farm Fence). Fabric:Galvanizedsteelwovenwirefarm fence. Line P o s t s : R e c y c l e d P l a s t i c . Corner,PullandEndPostAssemblies: Galvanized steel, timber, recycled plastic or concrete as specified in the Design Standards. TypeB(Chain-LinkFence). Metalposts
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2009/january-2009/workbook/sp5500200.pdf?sfvrsn=9e7f8227_0SP5500200
FENCING. (REV 1-6-98) (1-10) ARTICLE 550-2 (Page 690) is deleted and the following substituted: 550-2 Types of Fence. Thetypeoffencetobeconstructedisdesignatedasfollows: TypeA(Farm Fence). Fabric:Galvanizedsteelwovenwirefarm fence. Line P o s t s : R e c y c l e d P l a s t i c . Corner,PullandEndPostAssemblies: Galvanized steel, timber, recycled plastic or concrete as specified in the Design Standards. TypeB(Chain-LinkFence). Metalposts
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2010/january-2010/workbook/sp5500200.pdf?sfvrsn=3c791aa9_0E1W49BidTabs
SECTION: 0005 0550 10110 FENCING, TYPE A, 0.0-5.0', STANDARD 400.000 LF 30.00000 12,000.00 22.00000 8,800.00 20.00000 8,000.00 0010 0550 10221 FENCING, TYPE B, 5.1-6.0', W/ BARB WIRE ATTMT 100.000 LF 45.00000 4,500.00 98.46000 9,846.00 60.00000 6,000.00 0015 0550 10230 FENCING, TYPE B, 10238 FENCING, TYPE B, 6.1-7.0, RESET EXISTING 100.000 LF 58.00000 5,800.00 29.99000 2,999.00, FENCING, TYPE A, 0.0-5.0', STANDARD 400.000 LF 42.30000 16,920.00 100.00000 40,000.00 0010 0550
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/contracts/d1/bidtabs/2023/sep21/e1w49bidtabs.pdf?sfvrsn=e98c7c88_1Dev550FNC
FENCING. (REV 8-18-22) SECTION 550 is deleted and the following substituted: SECTION 550 FENCING 550-1 Description. Furnish, erect and reset metal fence of the type and at the locations, Innovative Products List (IPL). Construct this fencing in accordance with the manufacturer’s, certifying that the fencing system, materials, and construction practices comply with the applicable, removal of temporary fencing. 550-4.2 Spacing of Posts: For Types A, B, R and P2 fence, space posts
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/programmanagement/otherfdotlinks/developmental/files/dev550.pdf?sfvrsn=5ee289df_4550-011
: REVISION LAST of STANDARD PLANS FY 2024-25 SHEET INDEX BRIDGE FENCING ON PARAPET (CURVED TOP, . * Do not anchor fencing to the inside post) (1'-11ƀ" ± along 45°00'00" ~ (Typ.) (See Detail, , tension bars and bands, post and loop caps, base plates, Payment will be made under Fencing, Type, in the plans. Limits of fencing are from begin of approach slab at Begin Bridge to end of approach slab at End Bridge, unless otherwise LIMITS OF FENCING: railing as shown on Index 521-820. See
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/design/standardplans/2025/idx/550-011.pdf?sfvrsn=2c26ca76_1550-011
: REVISION LAST of STANDARD PLANS FY 2025-26 SHEET INDEX BRIDGE FENCING ON PARAPET (CURVED TOP, Railings. * Do not anchor fencing to the inside post) (1'-11ƀ" ± along 45°00'00" ~ (Typ.) (See Detail, , ties, tension bars and bands, post and loop caps, base plates, Payment will be made under Fencing, : shown in the plans. Limits of fencing are from begin of approach slab at Begin Bridge to end of approach slab at End Bridge, unless otherwise LIMITS OF FENCING: railing as shown on Index 521-820. See
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/design/standardplans/2026/idx/550-011.pdf?sfvrsn=c51efcc9_15500000SS
550 FENCING. (REV3-15-04)(FA3-29-04)(7-04) SECTION550(Pages623-628)isdeletedandthefollowingsubstituted: SECTION550 FENCING 550-1Description. Furnish,erectandresetmetal fence of the type, that the fencing system, materials and construction practices comply with the applicable Design, of temporary fencing. 550-4.2 Spacing of Posts: Space posts as shown in the Design Standards, . 550-6.1 Basic Items of Fencing: The Contract unit price per foot [meter] for the Item of Fencing
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2005/january-2005/workbook/5500000ss.pdf?sfvrsn=fbf46e6d_05500000SS
550 FENCING. (REV3-15-04)(FA3-29-04)(7-04) SECTION550(Pages623-628)isdeletedandthefollowingsubstituted: SECTION550 FENCING 550-1Description. Furnish,erectandresetmetal fence of the type, that the fencing system, materials and construction practices comply with the applicable Design, of temporary fencing. 550-4.2 Spacing of Posts: Space posts as shown in the Design Standards, . 550-6.1 Basic Items of Fencing: The Contract unit price per foot [meter] for the Item of Fencing
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2006/january-2006/workbook/5500000ss.pdf?sfvrsn=d81630ff_05500407.FHWA
Re: State Specifications Office Section: 550 Proposed Specification: 5500407 Fencing. Dear Mr, Construction Engineer 5500407 All Jobs FENCING. (REV 10-23-17) SUBARTICLE 550-4.7 is deleted, post. 5500407 All Jobs FENCING. (REV 10-23-17) SUBARTICLE 550-4.7 is deleted and the following
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2018/july-2018/review/fhwa/5500407.fhwa.pdf?sfvrsn=66fe8251_05500407.impl
550 FENCING. (REV 10-23-17) (FA 1-1-18) (7-18) SUBARTICLE 550-4.7 is deleted and the following substituted: 550-4.7 Electrical Grounds: 550-4.7.1 Grounding for Overhead Lines: Wherever an overhead power line crosses over the fence, install a ground rod directly below the point of crossing. Where an overhead power line runs parallel to, and within 100 feet of the fence, install a ground rod at each end of the fence and at intervals of no greater than 1,500 feet. Use copper-clad steel
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2018/july-2018/review/implemented/5500407.impl.pdf?sfvrsn=6574ce32_0D5500021.DO
FENCING. (REV 1-6-98) (7-02) ARTICLE 550-2 (Page 681). The text is deleted and the following substituted: Thetype of fence to be constructed is designated as follows: Type A (Farm Fence). Fabric:Galvanizedsteelwovenwirefarm fence. Line P o s t s : R e c ycled P l a s t i c . Corner,PullandEndPostAssemblies: Galvanized steel, timber, recycled plastic or concrete as specified in the Design Standards. Type B (Chain-Link Fence). Metalposts
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2003/january-2003/workbook/d5500021.do.pdf?sfvrsn=fcad008d_0D5500021.DO
FENCING. (REV 1-6-98) (7-02) ARTICLE 550-2 (Page 623). The text is deleted and the following substituted: Thetype of fence to be constructed is designated as follows: Type A (Farm Fence). Fabric:Galvanizedsteelwovenwirefarm fence. Line P o s t s : R e c ycled P l a s t i c . Corner,PullandEndPostAssemblies: Galvanized steel, timber, recycled plastic or concrete as specified in the Design Standards. Type B (Chain-Link Fence). Metalposts
https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2004/january-2004/workbook/d5500021.do.pdf?sfvrsn=53e385ee_0