834 search results for fencing

2025FDM122VarExcept

involving the use of fencing around stormwater management facilities. (3) Design Exceptions or Variations, Structures) X Design Variation: Fencing on Traffic Railing between pedestrians and travel lanes on LA, : Patterned Pavement Technical Special Provisions X Design Variation: Use of fencing around stormwater

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/roadway/fdm/2025/2025fdm122varexcept.pdf?sfvrsn=25d881bf_4

Workbook_for_1-11_2-17-11

Projects LIMITATIONS OF OPERATIONS – FENCING. (REV 6-17-04) (FA 7-13-04) (1-10) Change(s) to: 8-4.8, ) to: 550-2, 550-3.5, 550-6.2. SP5500200 Type A fencing on non- NHS Projects only PAINTED PAVEMENT, ) Changes to: 548-2. 548-6.5, 548-10 SS5480200 All J o b s 5 5 0 FENCING (REV 5-14-10) (FA 7-20-10

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/specifications/by-year/2011/january-2011/workbook/workbook_for_1-11_2-17-11.pdf?sfvrsn=31d4aabd_0

Developmental Specifications

Documents or established by the Engineer. Larry Jones N/A Dev550 - Fencing Use on jobs when

https://www.fdot.gov/specifications/developmental-specifications

E21P7-R0

SY 10.000 0527- 2- DETECTABLE WARNINGS SF 500.000 0550- 10-220 FENCING, TYPE B, 5.1-6.0', STANDARD

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/contracts/d2/lettings/2024/sep11/e21p7-r0.pdf?sfvrsn=ab039f49_1

TP-11-08-24BSN

956.000 0550- 10-333 FENCING, TYPE R, 6.1-7.0, W/FULL ENCLOSURE LF 292.000 0550- 10-353 FENCING, SYSTEM,TEMPORARY, EXCLUDING BARRIER SF 57,998.000 0550- 10-220 FENCING, TYPE B, 5.1-6.0', STANDARD LF 61,499.000 0550- 10-325 FENCING, TYPE R, 5.1-6.0', VERTICAL LF 6,004.000 0550- 60-224 FENCE GATE

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/contracts/tp/lettings/2024/nov08/tp-11-08-24bsn.pdf?sfvrsn=82bfd70f_1

TP-12-19-24BSN

2,684.000 0530- 74- BEDDING STONE TN 956.000 0550- 10-333 FENCING, TYPE R, 6.1-7.0, W/FULL ENCLOSURE LF 292.000 0550- 10-353 FENCING, TYPE R, 8.1 - 10.0', WITH FULL ENCLOSURE LF 2,184.000 0560, 0550- 10-220 FENCING, TYPE B, 5.1-6.0', STANDARD LF 61,525.000 0550- 10-325 FENCING, TYPE R

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/contracts/tp/lettings/2024/dec19/tp-12-19-24bsn.pdf?sfvrsn=ab934fcf_1

TP-01-17-25BSN

2,684.000 0530- 74- BEDDING STONE TN 956.000 0550- 10-333 FENCING, TYPE R, 6.1-7.0, W/FULL ENCLOSURE LF 292.000 0550- 10-353 FENCING, TYPE R, 8.1 - 10.0', WITH FULL ENCLOSURE LF 2,184.000 0560- 1-101, ,TEMPORARY, EXCLUDING BARRIER SF 48,467.000 0550- 10-220 FENCING, TYPE B, 5.1-6.0', STANDARD LF 61,525.000 0550- 10-325 FENCING, TYPE R, 5.1-6.0', VERTICAL LF 6,540.000 0550- 60-224 FENCE GATE, TYPE B

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/contracts/tp/lettings/2025/jan17/tp-01-17-25bsn.pdf?sfvrsn=944cdf11_1

Historical Item Averages Market Area 12

92.000 LF N FENCING, TYPE B, 0.5-5.0', W/ VINYL COATING 0550 10220 4 $22.17 $847,629.73 38,227.000 LF N FENCING, TYPE B, 5.1-6.0', STANDARD 0550 10221 1 $26.25 $649,162.50 24,730.000 LF N FENCING, TYPE B, 5.1-6.0', W/ BARB WIRE ATTMT 0550 10231 1 $26.25 $608,895.00 23,196.000 LF N FENCING, TYPE B, 6.1-7.0, W/ BARB WIRE ATTMT 0550 10240 1 $39.00 $35,061.00 899.000 LF N FENCING, TYPE B, 7.1-8.0', STANDARD 0550 10325 1 $100.00 $103,000.00 1,030.000 LF N FENCING, TYPE R, 5.1-6.0', VERTICAL 0550

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/programmanagement/estimates/reports/historical-item-average-costs-reports/moving/market-area/pdf/historical-item-averages-market-area-12.pdf?sfvrsn=2cade1d3_19

Developmental Specifications

Dev550FNC - Fencing Use on jobs when Developmental Standard Plan Index D550-804 is called

https://www.fdot.gov/programmanagement/otherfdotlinks/developmental/default.shtm
20 of 834 results