834 search results for fencing

Standard Plans - FY 2023-24 Errata

1 of 3 01/11/2023 Bridge Fencing (Over Railroad) Reverted to last year’s detail to correct

https://www.fdot.gov/design/standardplans/2024/Errata.shtm

4-2024-ADA

the pedestrian drop-off hazard cannot be eliminated , consider the following: (1) Fencing, pedestrian/bicycle bridge railings and fencing are provided in Figures 222.4.2 – 222.4.8. The installation of fencing on traffic railing between sidewalk or shared use paths and travel lanes on LA, with the District to determine when an enclosed fencing option is warranted. 65 66 5/7/2024, 70 69 70 5/7/2024 36 FIGURE 222.4.6 BRIDGE RAILING AND BRIDGE PARAPET FENCING 71 FIGURE

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/construction/training/2024-spring-construction-academy/4-2024-ada.pdf?sfvrsn=2e730c8d_1

550-011FHWAApprovedPkg

DESCRIPTION: REVISION LAST of STANDARD PLANS FY 2024-25 SHEET INDEX BRIDGE FENCING ON PARAPET 11/01/23, not anchor fencing to the inside post) (1'-11ƀ" ± along 45°00'00" ~ (Typ.) (See Detail on Sheet 2, , tension bars and bands, post and loop caps, base plates, Payment will be made under Fencing, Type R, in the plans. Limits of fencing are from begin of approach slab at Begin Bridge to end of approach slab at End Bridge, unless otherwise LIMITS OF FENCING: railing as shown on Index 521-820. See Index

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/design/standardplans/irr/2025/550-011fhwaapprovedpkg.pdf?sfvrsn=4b4698b7_1

fdot-bed25-977-08-rpt

is constantly having to work with the railroad agency to maintain the delineators. Fencing • Fences, the tracks or railroad right-of- way. • Fencing can be a good option at certain locations. • Fencing can prevent pedestrians from entering the railroad right-of-way but can also trap pedestrians, ON TRACKS”). • Adding pedestrian gate and fencing at HRGCs with frequent pedestrian trespassing

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/research/reports/fdot-bed25-977-08-rpt.pdf?sfvrsn=2703c309_1

D3-05-09-24BSN

FENCING, TYPE A, 0.0-5.0', STANDARD LF 1,000.000 0550- 10-118 FENCING, TYPE A, 0.0-5.0', TYPE A STANDARD, RESET EXISTING LF 500.000 0550- 10-150 FENCING, TYPE A, 8.1-10.0', STANDARD LF 5,000.000 0550- 10-158 FENCING, TYPE A, 8.1-10.0', RESET EXISTING LF 3,000.000 0550- 10-220 FENCING, TYPE B, 5.1-6.0', STANDARD LF 1,000.000 0550- 10-228 FENCING, TYPE B, 5.1-6.0, RESET EXISTING LF 1,000.000

https://fdotwww.blob.core.windows.net/sitefinity/docs/default-source/contracts/d3/lettings/2024/may09/d3-05-09-24bsn.pdf?sfvrsn=c067cf6f_1
20 of 834 results